Intrinsically safe 24 VDC compact interface module for use in hazardous areas, SIL systems

Field of application

The 1- or 2-channel RN22 active barrier powers analog instrument loops and safety instrumented systems up to SIL 2 (SC 3). The intrinsically safe, HART® transparent interface establishes a reliable link between field devices and process control. It interfaces with 2-/4-wire devices in hazardous areas and provides a second galvanically isolated signal output acc. to NAMUR NE 175. This opens a second channel for the process optimization domain without affecting the traditional automation system.

  • Single- or two-channel active barrier, power supply or signal doubler

  • 0/4 to 20 mA analog signal transmission (NAMUR NE 43) and galvanic isolation

  • Intrinsic safety for operation in hazardous areas (Zone 2)

  • Bidirectional HART® communication (transparent)

  • 2- and 4-wire capability for instruments in hazardous areas (Zones 0/20)

  • Ambient temperature range: -40 … 60 °C (-40 … 140 °F)

Benefits

  • Intrinsically safe interface device suited for use in safety instrumented systems up to SIL 2 (SC 3) in accordance with IEC 61508

  • Quick and easy wiring with screw or push-in terminals or power supply via power rail T-connector

  • Easy access to frontside HART® connection taps

  • Compact housing: up to two channels on 12.5 mm (0.49 in) for efficient use of space in control cabinets

Specifications

Measuring principle

Active barrier

Measuring principle

Active barrier

Function

1-channel
2-channel
Signal doubler

Loop power supply

17,5 V ±1 V bei 20 mA open circuit
voltage: 24,5 V ±5 %

Power Supply

24 V DC

Input

0/4…20 mA / HART
feeding/not feeding

Output

0/4…20 mA / HART
active/passive

Certificates

ATEX II3G Ex tc IIIC Dc
CSA C/US AIS, I/2/ABCD
EAC [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ec IIC Gc
JPN [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ec IIC Gc
KC [Ex ia Ga] IIC,[Ex ia Da] IIIC, Ex ec IIC Gc
INMETRO [Ex ia Ga] IIC,[Ex ia Da] IIIC, Ex ec IIC Gc
NEPSI [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ec IIC Gc
UK II3G Ex tc IIIC Dc
UK II(1)G [Ex ia Ga] IIC, II(1)D [Ex ia Da] IIIC, II3G Ex ec IIC Gc
ATEX IECEx II(1)G [Ex ia Ga] IIC, II(1)D [Ex ia Da] IIIC, II3G Ex ec IIC Gc
UL C/US
DNV

SIL

SIL 2 SC 3

Operation

HART