Цифровий датчик провідності Indumax CLS54D, Endress+Hauser
Memosens toroidal conductivity sensor for hygienic and sterile applications
Field of applicationThe Indumax CLS54D inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products. Thanks to Memosens digital technology, Indumax CLS54D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration, and facilitates predictive maintenance. Indumax CLS54D measures toroidal conductivity in hygienic food & beverage and life science applications, such as:
| Benefits
|
Specifications
| Measuring principle | Inductive |
| Application | Food, beverage and pharmaceutical industries, biotechnology, dairies, breweries |
| Characteristic | Specifically intended for use in hygienic applications and especially suitable for following applications: |
| Measurement range | 100 µS/cm to 2000 mS/cm |
| Measuring principle | Inductive conductivity measurement |
| Design | Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications |
| Material | In contact with medium: virgin PEEK |
| Process temperature | -10 °C to 125 °C (14 °F to 257 °F) |
| Process pressure | 13 bar abs up to 90 °C (188.5 psi abs up to 194 °F) |
| Temperature sensor | Pt1000 (Class A according to IEC 60751) |
| Connection | Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50 |
| Ingress protection | IP68 / NEMA type 6P |
| Additional certifications | FDA, EHEDG, 3-A |