A versatile probe for your Raman spectroscopy needs

Field of application

Designed for product and process development, the Rxn-10 probe is the workhorse of the Raman probe portfolio. It is trusted to deliver high performance Raman measurements across a wide spectral range. It is also compact, lightweight, and flexible, offering multi-purpose convenience for solids and liquids analysis in the laboratory environment. The Rxn-10 probe accepts a variety of interchangeable optics, making it a highly versatile and easily adaptable instrument in your laboratory toolbox.

  • Chemical: reaction monitoring, blending, catalysis, hydrocarbon speciation, process unit optimization

  • Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending

  • Pharmaceutical: API reaction monitoring, crystallization

  • Biopharmaceutical: monitoring, optimization, and control of cell culture, fermentation, and downstream applications

  • Food & Beverage: zonal heterogeneity mapping of meats and fish

Benefits

  • Multipurpose use for both solids and liquids measurement

  • Lightweight and compact

  • Integrated laser safety interlock, including “laser on” indication and probe shutter

  • Flexible output compatible with a range of sampling options

  • Easy switching of non-contact, immersion, and bioprocessing optics to suit a variety of applications

  • Wide spectral range, including access to the critical low-wavenumber region

Specifications

Measuring principle

Raman spectroscopy

Spectral coverage

Probe spectral coverage is limited by the coverage of the analyzer being used.

Temperature

Temperature, Rxn-10 probe:
-10 to 70 °C / 14 to 158 °F

Relative humidity

20 to 60 %, non-condensing

Maximum laser power into probehead (mW)

< 499

Sample interface

Based on the sampling optic selected

Body and window materials

Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel

Fiber optic cable

Design: PVC jacketed, proprietary construction
Connections: proprietary electro-optic (EO), or FC to EO fiber converter(s) for non-embedded systems
Temperature:
-40 to 70 °C / -40 to 158 °F
Standard length:
5000 mm / 196.86 inch
25000 mm / 984.26 inch
Also available in 5000 mm / 196.86 inch increments
Minimum bend radius:
152.4 mm / 6 inch

Length

Rxn-10 probe (including fiber cable bend radius): 356 mm / 14.02 inch

Diameter

Rxn-10 probe:
19 mm / 0.75 inch

Working distance

Based on the sampling optic selected