iTHERM TM412 Гігієнічний термометр, американське виконання, Endress+Hauser

iTHERM TM412 Гігієнічний термометр, американське виконання, Endress+Hauser
Попереднє замовлення
Доступне передзамовлення
Endress+Hauser Виробник: Endress+Hauser
Без ПДВ: 0.00UAH

For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

Field of application

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.

  • Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

  • Measuring range: –200 to +600 °C (–28 to +1 112 °F)

  • Pressure range up to 40 bar (580 psi)

  • Protection class: up to IP69K

Benefits

  • User-friendly and reliable from product selection to maintenance

  • iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values

  • iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control

  • iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety

  • iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration

  • iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating

  • International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability

Specifications

Measuring principle

Resistance Temperature Detector

Characteristic / Application

imperial style
modular temperature assembly
hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
hygienic process connections
with neck
suitable for hazardous areas
incl. protection tube
QuickSens for fastest response time
StrongSens for most robust design
QuickNeck for easy and cost saving recalibration








Thermowell / protection tube

without
incl. thermowell
incl. Tee-/elbow thermowell

Insert / probe

mineral insulated (MI), flexible
pipe version, isolated wires, not flexible

Outer diameter protection tube / Insert

1/4'' (6,35 mm)
3/8'' (9,53 mm)
1/2" (12,7 mm)

Max. immersion length on request

48"

Material protection tube/ thermowell

316L

Process connection

Weld-in adapter
Tri-clamp
Clamp-connections according to ISO2852
G3/4" Liquiphant
G1" Liquiphant
Varivent
T- and elbow thermowell

Tip shape

straight
reduced

Surface roughness Ra

30 μin (0,76 μm)
15 μin (0,38 μm )
15 μin (0,38 μm) electropolished

Operating temperature range

PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)

Max. process pressure (static)

at 20 °C: 40 bar (580 psi)

Accuracy

class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s

Integration head transmitter

yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

ATEX II 3 G Ex nA IIC T6, II3D
CSA General Purpose, CSA C/US
CSA C/US IS, NI I/1+2/A-D
CSA NI I/2/A-D
CSA IS, NI I/1+2/A-D
FM NI I / 2/A-D
FM IS, NI I/1+2/A-D
ATEX IECEx II1G Ex ia IIC T6 Ga
FM+CSA IS, NI I/1+2/A-D
ATEX IECEx II1/2D Ex tb IIIC Da/Db
ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb
ATEX IECEx II1/2D Ex ia IIIC Da/Db

Certification

SIL (transmitter only)