TEC420 Термопарний термометр, Endress+Hauser
Comprehensive and common temperature measurement technology for almost all branches of industry
Field of applicationThe high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities. TEC420 sheathed thermocouples cover temperature ranges from -40°C to 1100°C depending on the type of thermocouple. They can be used in low pressure applications in direct contact with the medium or protected by a thermowell. They can also be used in all applications where small immersion lengths are needed. Special attention should be paid to the maximum operating temperature of the connection head (80 °C if transmitter included). | Benefits
|
Specifications
| Measuring principle | Thermocouple |
| Characteristic / Application | metric style |
| Thermowell / protection tube | without (not intended to use with thermowell) |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 6,0 mm (0,24'') |
| Max. immersion length on request | up to 100.000,00 mm (3.937,01'') |
| Material protection tube/ thermowell | 1.4401 (316) |
| Process connection | depending on configuration |
| Operating temperature range | -40 °C ...1.100 °C |
| Max. process pressure (static) | at 20 °C: 20 bar (290 psi) |
| Accuracy | class 2 acc. to IEC 60584 |
| Response time | t50 = 3 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX |
| Certification | SIL (transmitter only) |